Optical Coordimeter

used to monitor deformation processes

The Optical Coordimeter is used to monitor the deformation behavior inside of water dams. For that purpose steel wires are solidly installed into the dam wall and run through it vertically. The achievable accuracy is within several tenths of a millimeter.

  • Article number: 108200:001.22 – Optical Coordimeter

Downloads

Measuring range 180 - 340 mm
Graduation of the horizontal scale 1 mm
Graduation of the micrometer vernier 0.01 mm
Telescope Shortest target distance 160 mm
max. target distance 500 mm
Size 450 x 450 x 200 mm
Weight Coordimeter 8.7 kg
with carrying case 16.5 kg

Using the Optical Coordimeter, the position of a plumb wire in relation to the alignment plane (parallel to it or in cross direction) can be determined with an accuracy of ± 0.1 mm. To do that the Optical Coordimeter is attached to a solidly installed wall mount bracket with forced centering mechanism.

The Coordimeter consists of two arms with horizontal gauges that are placed perpendicularly to each other. The measurement value is read off a micrometer vernier with a graduation of 0.1 mm. When taking a measurement, the telescopes are targeted toward the left or right edge of the plum wire.

Example of use

  • monitoring of the deformation behavior inside of water dams

Accessories

  • wall mount bracket for Optical Coordimeter (108300:001.10)

The Optical Coordimeter is used to monitor the deformation behavior inside of water dams. For that purpose steel wires are solidly installed into the dam wall and run through it vertically. The achievable accuracy is within several tenths of a millimeter.

  • Article number: 108200:001.22 – Optical Coordimeter

Downloads

Measuring range 180 - 340 mm
Graduation of the horizontal scale 1 mm
Graduation of the micrometer vernier 0.01 mm
Telescope Shortest target distance 160 mm
max. target distance 500 mm
Size 450 x 450 x 200 mm
Weight Coordimeter 8.7 kg
with carrying case 16.5 kg

Using the Optical Coordimeter, the position of a plumb wire in relation to the alignment plane (parallel to it or in cross direction) can be determined with an accuracy of ± 0.1 mm. To do that the Optical Coordimeter is attached to a solidly installed wall mount bracket with forced centering mechanism.

The Coordimeter consists of two arms with horizontal gauges that are placed perpendicularly to each other. The measurement value is read off a micrometer vernier with a graduation of 0.1 mm. When taking a measurement, the telescopes are targeted toward the left or right edge of the plum wire.

Example of use

  • monitoring of the deformation behavior inside of water dams

Accessories

  • wall mount bracket for Optical Coordimeter (108300:001.10)